Home > Relays > Intrinsically Safe Relays >

Macromatic ISEUR1 1 Channel Intrinsically Safe Relay, 102-132VAC / 10-125VDC, Standard Logic


Macromatic 1 Channel Intrinsically Safe Relay, 102-132VAC / 10-125VDC
Macromatic ISEUR1 1 Channel Intrinsically Safe Relay, 102-132VAC / 10-125VDC, Standard Logic
 
Alternative Views:


Price: $112.93
Note: Ships in 10-15 Business Days. Contact us to confirm current ship date
MFG P/N: ISEUR1
MFG: Macromatic
Weight (lbs): 0.3



Availability:
In Stock
Product Code: ISEUR1
Qty:

Description
 

The Macromatic ISEUR1 is a single channel intrinsically safe relay. This DIN-rail or panel mount relay has an input voltage of 102-132VAC / 10-125VDC. It helps to monitor a load from a hazardous location and has an output of 5A SPST-NO. It can be used in Class I Div 1 Groups A, B, C, and D, Class II Div 1 Groups E, F, and G, and Class III Div 1. It has a 17.5mm wide housing. The LED shows the status of the relay. Please note that the relay itself needs to be installed in a safe area.

Specifications

  • Relay Function- Intrinsically Safe Single Channel
  • Input Voltage- 102-132VAC / 10-125VDC
  • Output- 5A SPST-NO
  • Load- 2VA Max
  • Input Switch Open Circuit Voltage- 10V DC
  • Operating Temperature- -28 C to 60 C (-18 F to 140 F)
  • Storage Temperature- -55 C to 85 C (-67 F to 185 F)
  • Output Contacts- SPST-NO 3A Resistive @ 125V AC @ 60 C & 30V DC Resistive, Pilot Duty Rating D300; SPST-NO 5A Resistive @ 125V AC @ 40 C & 30V DC Resistive, Pilot Duty Rating D300
  • Life- Mechanical: 5 Million Closures @ No Load, Electrical: 50,000 Closures @ Full Load AC
  • Response Time- <50ms
  • Insulation Voltage- 1500VAC between coil & contacts, 750VAC between open contacts, 1500VAC between hazardous & safe circuits
  • Wire Sizes- One 14-24 AWG Conductor or Two 16 or 18 AWG Conductors
  • Housing Dimensions- 3.58" Height x 0.69" Width x 2.6" Depth
  • Approvals- UL & CUL Listed, CE

This single channel relay operates in Standard mode. The LED is green when input voltage is introduced. In Standard mode the LED is orange when the output contact is closed. When the output contact is closed, the input device is also closed, and vice versa.

Macromatic ISE Series Relay Installation Manual

Macromatic Single Channel DIN-Rail Mount Intrinsically Safe Relay




Meltric 596P0N12 DS200 Metal Handle, 1-1/4" NPT Entry $509.15
GardTec GCAB704 Cooling Fan Kit, 120 mm, Wire Fan Guard, 120V, w/ Thermostat, High Speed $51.63
Imprint Technologies MB400 2" Black Hot Stamp Foil $14.98
Mencom 229M PG 29 Lock Nut, Nickel Plated Brass $1.97
Menics PREF-301-RYG 56 mm 3 Stack LED Tower Light, Red Yellow Green, Flashing, 12V $142.52
Mencom MDCM-8MP-2M M12 Cordset, 8 Pole, Male Straight, 2 M, Shielded $34.39
Mencom USBAA-03 Panel Interface Connector Cable, USB Form A to Form A, 3 Feet $5.42
ILME TMAP-10.25 T-Type Surface Mount Housing, Size 57.27, Double Lever, M25 $29.40