Voltage Indication and Suppression
The 24V DC LED indicator provides a visual confirmation of the voltage supply at the connector. MOV suppression provides overvoltage protection for the source and load. Select this circuit configuration where both voltage indication and MOV suppression are required.
Terminal Construction and Locking
The patent-protected combination terminal supports flexible wire fitted with wire-end ferrules. It also accommodates fork-type cable shoes or eye terminals directly under the screw head. Screw connections include conductor protection, and the central fixing screw provides vibration-resistant locking at the mating connection.
Key Features
- Clear housing and LED indication provide a visible voltage-supply check.
- MOV suppression provides overvoltage protection for the source and load.
- Screw terminals include conductor protection for hardwired connections.
- The combination terminal accommodates flexible wire with ferrules, fork-type cable shoes, or eye terminals.
- Central screw locking provides a vibration-resistant connection.
- The included gasket forms part of the IP65 connector assembly.
Applications
Use this Form A connector with compatible hydraulic, pneumatic, and electromagnetic actuators, including solenoid valves, pressure sensors, and flow indicators. The right-angle housing and hardwired terminals support equipment wiring where a detachable actuator connection and visible supply indication are required.
Installation and Selection Notes
- Confirm the mating interface is Form A with 18 mm contact spacing and two poles plus ground.
- Select cable with an outside diameter of 4.5–7 mm for the PG 9 entry.
- Use conductors within the maximum 16 AWG capacity and the appropriate terminal connection method.
- Check that the 24V DC indicator and MOV suppression circuit matches the electrical application.
- Fit the included NBR profile gasket and secure the connector with the M3 × 37 mm center screw.
The connector provides IP65 protection under IEC 60529 when correctly assembled. Check the gasket fit and connector assembly for the installation environment. See the connector images for dimensional drawings.
Compatibility Notes
This connector may be compatible with MPM/Woodhead S18209TC421 (Housing height 27 mm, 6-8 mm cable entry) and CNE KA132V54T9 (Housing height 30.2 mm, 5-7 mm cable entry).
Confirm the mating interface, circuit function, gasket, housing clearance, and cable diameter before selecting a replacement. The alternative connector dimensions and cable-entry ranges differ from those of this Hirschmann connector.
Connector Guides
Guide to DIN 43650 Solenoid Valve Connectors