Home > Industrial Ethernet Switches > Hirschmann Ethernet Switches > Hirschmann 24 Port Industrial Ethernet Switches >

Hirschmann 942170088 BRS30-24TX-EEC 24 Port Managed Gigabit Ethernet Switch, Extended Temp Range


Hirschmann BRS30-24TX-EEC Managed Gigabit Switch
Hirschmann 942170088 BRS30-24TX-EEC 24 Port Managed Gigabit Ethernet Switch, Extended Temp Range
 
Alternative Views:


Price: $3,683.38
Note: Please call or email [email protected] for alternatives
MFG P/N: 942170088
MFG: Hirschmann / Belden
Ships From: Eastlake, OH
Weight (lbs): 2.5

Quantity in Stock :(Out of Stock)


Availability:
Out of Stock
Product Code: 942170-088
Email [email protected] for a quote

  
Description
 

Hirschmann BRS30-24TX-EEC 24-Port Managed Industrial Ethernet Switch with Gigabit Uplinks

Part Number 942170-088 | BOBCAT Series | DIN rail

Industrial Network Connectivity and Control

The Hirschmann BRS30-24TX-EEC (part number 942170-088) is a 24-port managed industrial Ethernet switch in the BRS BOBCAT series. It combines 20 10/100BASE-TX RJ45 ports with four 10/100/1000BASE-TX RJ45 ports, providing Fast Ethernet device connections and Gigabit uplinks in one switch. The fanless design and metal housing support DIN rail installation in industrial network systems.

Time-Sensitive Networking (TSN) supports real-time communication. Managed switching functions provide VLAN segmentation and traffic prioritization, while network diagnostics and access controls support network administration. The operating temperature range is -40 °C to +70 °C (-40 °F to 158 °F). This extended temperature range suits installations exposed to wider ambient temperature changes. A five-year manufacturer’s guarantee applies.

Features and Benefits

  • 20 Fast Ethernet ports and four Gigabit-capable RJ45 ports for mixed-speed networks.
  • Time-Sensitive Networking (TSN) for real-time communication.
  • Fanless construction for operation without a cooling fan.
  • Metal housing with DIN rail mounting.
  • VLAN and QoS functions for network segmentation and traffic prioritization.
  • USB-C for local management and device replacement.
  • Extended operating temperature range of −40 °C to +70 °C.

Applications and Recommended Uses

Recommended uses include automation cells that combine Fast Ethernet device connections with Gigabit uplinks. This port arrangement supports local machine communications while providing higher-speed connections to other switches or supervisory systems.

  • Machine control panels connecting PLCs, HMIs, drives, and remote I/O over 10/100 Ethernet.
  • Packaging or assembly lines that connect local control devices to a Gigabit plant network.
  • Material handling systems linking conveyor control equipment through managed Ethernet.
  • Production cells requiring VLAN segmentation and prioritized control traffic.

The −40 °C to +70 °C operating range makes this variant a candidate for enclosed automation installations with wider ambient temperature changes. Match the installation to the switch’s IP30 protection rating and specified humidity limits.

Installation and Network Planning

Allow space for the switch dimensions and the required cable connections when planning the DIN rail layout. Use the specified 12–24 V DC power inputs and keep the installation within the operating temperature and humidity limits.

Twisted-pair connections support cable lengths up to 100 m. Review the BOBCAT series manual for wiring, configuration, and installation requirements before commissioning the network.

Manual and Product Resources

Hirschmann BRS BOBCAT Series Manual

Managed Ethernet Switch Comparison Chart

Technical Specifications

ManufacturerHirschmann
ModelBRS30-24TX-EEC
Part number942170-088
SeriesBRS BOBCAT
Switch typeManaged industrial Ethernet switch with Gigabit uplinks
Ports20 × 10/100BASE-TX RJ45; 4 × 10/100/1000BASE-TX RJ45
HousingMetal
CoolingFanless
Manufacturer’s guarantee5 years
Operating voltage2 × 12–24 V DC
Power consumption16 W
Heat dissipation55 BTU/h

Interfaces

Power supply/signaling contact1 plug-in terminal block, 6-pin
Local management and device replacementUSB-C

Ambient Conditions

Operating temperature-40 °C to +70 °C (-40 °F to 158 °F)
Storage/transport temperature-40 °C to +70 °C (-40 °F to 158 °F)
Relative humidity (non-condensing)1% to 95%

Mechanical Construction

Dimensions (W × H × D)122.4 mm x 140 mm x 105.5 mm (4.82" x 5.51" x 4.15")
MountingDIN rail
Protection classIP30

Cable Length and Network Topology

Twisted pair (TP)0–100 m
Line and star topologyUnrestricted cascading

Software and Network Capabilities

Switching

Independent VLAN Learning, Fast Aging, Static Unicast/Multicast Address Entries, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, Queue-Shaping / Max. Queue Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), GARP VLAN Registration Protocol (GVRP), Voice VLAN, GARP Multicast Registration Protocol (GMRP), IGMP Snooping/Querier per VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP).

Redundancy

HIPER-Ring (Ring Switch), Link Aggregation with LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), Redundant Network Coupling, RSTP 802.1D-2004 (IEC62439-1), RSTP Guards.

Management

Dual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet, IPv6 Management, OPC UA Server.

Diagnostics

Management Address Conflict Detection, MAC Notification, Signal Contact, Device Status Indication, TCPDump, LEDs, Syslog, Persistent Logging on ACA, Port Monitoring with Auto-Disable, Link Flap Detection, Overload Detection, Duplex Mismatch Detection, Link Speed and Duplex Monitoring, RMON (1,2,3,9), Port Mirroring 1:1, Port Mirroring 8:1, Port Mirroring N:1, Port Mirroring N:2, System Information, Self-Tests on Cold Start, Copper Cable Test, SFP Management, Configuration Check Dialog, Switch Dump.

Configuration

Automatic Configuration Undo (roll-back), Configuration Fingerprint, Text-based Configuration File (XML), Backup config on a remote server when saving, Clear config but keep IP settings, BOOTP/DHCP Client with Auto-Configuration, DHCP Server: per Port, DHCP Server: Pools per VLAN, Auto-Configuration Adapter ACA21/22 (USB), HiDiscovery, USB-C Management support, Command Line Interface (CLI), CLI Scripting, CLI script handling over ENVM at boot, Full-featured MIB Support, Context-sensitive Help, HTML5-based Management.

Security

ISASecure CSA / IEC 62443-4-2 certified, MAC-based Port Security, Port-based Access Control with 802.1X, Guest/unauthenticated VLAN, Integrated Authentication Server (IAS), RADIUS VLAN Assignment, Denial-of-Service Prevention, DoS Prevention Drop Counter, VLAN-based ACL, Ingress VLAN-based ACL, Basic ACL, Access to Management restricted by VLAN, Device Security Indication, Audit Trail, CLI Logging, HTTPS Certificate Management, Restricted Management Access, Appropriate Use Banner, Configurable Password Policy, Configurable Number of Login Attempts, SNMP Logging, Multiple Privilege Levels, Local User Management, Remote Authentication via RADIUS, User Account Locking, Password change on first login.

Industrial Profiles

EtherNet/IP Protocol, IEC61850 Protocol (MMS Server, Switch Model), Modbus TCP, PROFINET Protocol.

Time Synchronization

PTPv2 Transparent Clock two-step, PTPv2 Boundary Clock, Boundary Clock with up to 8 synchronizations/s, 802.1AS, Buffered Real Time Clock, SNTP Client, SNTP Server.

Miscellaneous

Digital IO Management, Manual Cable Crossing, Port Power Down.

Mechanical Stability

IEC 60068-2-27 shock15 g, 11 ms duration
IEC 60068-2-6 vibration5 Hz–8.4 Hz with 3.5 mm amplitude; 2 Hz–13.2 Hz with 1 mm amplitude; 8.4 Hz–200 Hz with 1 g; 13.2 Hz–100 Hz with 0.7 g

EMC Interference Immunity

EN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10 V/m (80-2000 MHz); 5 V/m (2000-2700 MHz); 3 V/m (5100-6000 MHz)
EN 61000-4-4 fast transients (burst)2 kV power line, 2 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth) and 1 kV (line/line); data line: 2 kV
EN 61000-4-6 conducted immunity10 V (150 kHz-80 MHz)

EMC Emissions

FCC CFR47 Part 15FCC CFR47 Part 15 Class A
EN 55032EN 55032 Class A

Approvals

Safety of industrial control equipmentcUL 61010
Standards and markingsCE, FCC, EN61131, EN62368-1

Scope of Delivery and Accessories

The scope of delivery includes the switch, a terminal block for the supply voltage and signaling contact, and a safety and general information sheet.