Industrial Network Connectivity and ControlThe Hirschmann BRS30-24TX-EEC (part number 942170-088) is a 24-port managed industrial Ethernet switch in the BRS BOBCAT series. It combines 20 10/100BASE-TX RJ45 ports with four 10/100/1000BASE-TX RJ45 ports, providing Fast Ethernet device connections and Gigabit uplinks in one switch. The fanless design and metal housing support DIN rail installation in industrial network systems. Time-Sensitive Networking (TSN) supports real-time communication. Managed switching functions provide VLAN segmentation and traffic prioritization, while network diagnostics and access controls support network administration. The operating temperature range is -40 °C to +70 °C (-40 °F to 158 °F). This extended temperature range suits installations exposed to wider ambient temperature changes. A five-year manufacturer’s guarantee applies. Features and Benefits- 20 Fast Ethernet ports and four Gigabit-capable RJ45 ports for mixed-speed networks.
- Time-Sensitive Networking (TSN) for real-time communication.
- Fanless construction for operation without a cooling fan.
- Metal housing with DIN rail mounting.
- VLAN and QoS functions for network segmentation and traffic prioritization.
- USB-C for local management and device replacement.
- Extended operating temperature range of −40 °C to +70 °C.
Applications and Recommended UsesRecommended uses include automation cells that combine Fast Ethernet device connections with Gigabit uplinks. This port arrangement supports local machine communications while providing higher-speed connections to other switches or supervisory systems. - Machine control panels connecting PLCs, HMIs, drives, and remote I/O over 10/100 Ethernet.
- Packaging or assembly lines that connect local control devices to a Gigabit plant network.
- Material handling systems linking conveyor control equipment through managed Ethernet.
- Production cells requiring VLAN segmentation and prioritized control traffic.
The −40 °C to +70 °C operating range makes this variant a candidate for enclosed automation installations with wider ambient temperature changes. Match the installation to the switch’s IP30 protection rating and specified humidity limits. Installation and Network PlanningAllow space for the switch dimensions and the required cable connections when planning the DIN rail layout. Use the specified 12–24 V DC power inputs and keep the installation within the operating temperature and humidity limits. Twisted-pair connections support cable lengths up to 100 m. Review the BOBCAT series manual for wiring, configuration, and installation requirements before commissioning the network. Technical Specifications| Manufacturer | Hirschmann |
|---|
| Model | BRS30-24TX-EEC |
|---|
| Part number | 942170-088 |
|---|
| Series | BRS BOBCAT |
|---|
| Switch type | Managed industrial Ethernet switch with Gigabit uplinks |
|---|
| Ports | 20 × 10/100BASE-TX RJ45; 4 × 10/100/1000BASE-TX RJ45 |
|---|
| Housing | Metal |
|---|
| Cooling | Fanless |
|---|
| Manufacturer’s guarantee | 5 years |
|---|
| Operating voltage | 2 × 12–24 V DC |
|---|
| Power consumption | 16 W |
|---|
| Heat dissipation | 55 BTU/h |
|---|
Interfaces| Power supply/signaling contact | 1 plug-in terminal block, 6-pin |
|---|
| Local management and device replacement | USB-C |
|---|
Ambient Conditions| Operating temperature | -40 °C to +70 °C (-40 °F to 158 °F) |
|---|
| Storage/transport temperature | -40 °C to +70 °C (-40 °F to 158 °F) |
|---|
| Relative humidity (non-condensing) | 1% to 95% |
|---|
Mechanical Construction| Dimensions (W × H × D) | 122.4 mm x 140 mm x 105.5 mm (4.82" x 5.51" x 4.15") |
|---|
| Mounting | DIN rail |
|---|
| Protection class | IP30 |
|---|
Cable Length and Network Topology| Twisted pair (TP) | 0–100 m |
|---|
| Line and star topology | Unrestricted cascading |
|---|
Software and Network CapabilitiesSwitchingIndependent VLAN Learning, Fast Aging, Static Unicast/Multicast Address Entries, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, Queue-Shaping / Max. Queue Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), GARP VLAN Registration Protocol (GVRP), Voice VLAN, GARP Multicast Registration Protocol (GMRP), IGMP Snooping/Querier per VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP). RedundancyHIPER-Ring (Ring Switch), Link Aggregation with LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), Redundant Network Coupling, RSTP 802.1D-2004 (IEC62439-1), RSTP Guards. ManagementDual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet, IPv6 Management, OPC UA Server. DiagnosticsManagement Address Conflict Detection, MAC Notification, Signal Contact, Device Status Indication, TCPDump, LEDs, Syslog, Persistent Logging on ACA, Port Monitoring with Auto-Disable, Link Flap Detection, Overload Detection, Duplex Mismatch Detection, Link Speed and Duplex Monitoring, RMON (1,2,3,9), Port Mirroring 1:1, Port Mirroring 8:1, Port Mirroring N:1, Port Mirroring N:2, System Information, Self-Tests on Cold Start, Copper Cable Test, SFP Management, Configuration Check Dialog, Switch Dump. ConfigurationAutomatic Configuration Undo (roll-back), Configuration Fingerprint, Text-based Configuration File (XML), Backup config on a remote server when saving, Clear config but keep IP settings, BOOTP/DHCP Client with Auto-Configuration, DHCP Server: per Port, DHCP Server: Pools per VLAN, Auto-Configuration Adapter ACA21/22 (USB), HiDiscovery, USB-C Management support, Command Line Interface (CLI), CLI Scripting, CLI script handling over ENVM at boot, Full-featured MIB Support, Context-sensitive Help, HTML5-based Management. SecurityISASecure CSA / IEC 62443-4-2 certified, MAC-based Port Security, Port-based Access Control with 802.1X, Guest/unauthenticated VLAN, Integrated Authentication Server (IAS), RADIUS VLAN Assignment, Denial-of-Service Prevention, DoS Prevention Drop Counter, VLAN-based ACL, Ingress VLAN-based ACL, Basic ACL, Access to Management restricted by VLAN, Device Security Indication, Audit Trail, CLI Logging, HTTPS Certificate Management, Restricted Management Access, Appropriate Use Banner, Configurable Password Policy, Configurable Number of Login Attempts, SNMP Logging, Multiple Privilege Levels, Local User Management, Remote Authentication via RADIUS, User Account Locking, Password change on first login. Industrial ProfilesEtherNet/IP Protocol, IEC61850 Protocol (MMS Server, Switch Model), Modbus TCP, PROFINET Protocol. Time SynchronizationPTPv2 Transparent Clock two-step, PTPv2 Boundary Clock, Boundary Clock with up to 8 synchronizations/s, 802.1AS, Buffered Real Time Clock, SNTP Client, SNTP Server. MiscellaneousDigital IO Management, Manual Cable Crossing, Port Power Down. Mechanical Stability| IEC 60068-2-27 shock | 15 g, 11 ms duration |
|---|
| IEC 60068-2-6 vibration | 5 Hz–8.4 Hz with 3.5 mm amplitude; 2 Hz–13.2 Hz with 1 mm amplitude; 8.4 Hz–200 Hz with 1 g; 13.2 Hz–100 Hz with 0.7 g |
|---|
EMC Interference Immunity| EN 61000-4-2 electrostatic discharge (ESD) | 6 kV contact discharge, 8 kV air discharge |
|---|
| EN 61000-4-3 electromagnetic field | 10 V/m (80-2000 MHz); 5 V/m (2000-2700 MHz); 3 V/m (5100-6000 MHz) |
|---|
| EN 61000-4-4 fast transients (burst) | 2 kV power line, 2 kV data line |
|---|
| EN 61000-4-5 surge voltage | power line: 2 kV (line/earth) and 1 kV (line/line); data line: 2 kV |
|---|
| EN 61000-4-6 conducted immunity | 10 V (150 kHz-80 MHz) |
|---|
EMC Emissions| FCC CFR47 Part 15 | FCC CFR47 Part 15 Class A |
|---|
| EN 55032 | EN 55032 Class A |
|---|
Approvals| Safety of industrial control equipment | cUL 61010 |
|---|
| Standards and markings | CE, FCC, EN61131, EN62368-1 |
|---|
Scope of Delivery and AccessoriesThe scope of delivery includes the switch, a terminal block for the supply voltage and signaling contact, and a safety and general information sheet.
|
|
 |
 |
 |
 |

|