Match the Right Mega Electronics Power Cord

Match the Right Mega Electronics Power Cord Faster

Build or service equipment with a cord matched to the destination, inlet, current draw and application. Compare Mega Electronics power cords in one practical guide.

Shop Mega Electronics Power Cords

Fast answer: Choose the plug standard for the destination, confirm the equipment inlet or stripped-wire termination, then select a cord rated at or above the equipment current and voltage. Finally, verify wire gauge, length and required approvals.

🧭 Five Checks Before You Select a Power Cord

Use this sequence to narrow the options without relying on plug appearance alone.

1. Region

Match the wall plug to the country or regional standard.

2. Device End

Choose C13, right-angle C13, C14 or stripped conductors.

3. Rating

Confirm voltage and current against the equipment nameplate.

4. Cable

Check 18, 16 or 14 AWG and the required reach.

5. Approval

Verify UL, CSA or destination-specific certification.

🇺🇸 North American Power Cords

Use detachable C13 cords for equipment with an IEC 60320-C14 inlet. Choose a stripped-end cord when the cable will be terminated inside approved equipment by a qualified assembler. These 125 V options use NEMA 5-15P plugs and cover 10 A, 13 A and 15 A applications.

Part Number Equipment End Cable Length Rating
17251 C13 SVT, 18 AWG 2.29 m / 7 ft 6 in 10 A, 125 V
17500 C13 SJT, 18 AWG 2 m / 6 ft 7 in 10 A, 125 V
17502 C13 SJT, 16 AWG 2 m / 6 ft 7 in 13 A, 125 V
17504 C13 SJT, 14 AWG 2 m / 6 ft 7 in 15 A, 125 V
17505 C13 SJT, 14 AWG 3 m / 9 ft 10 in 15 A, 125 V
17506 Right-angle C13 SJT, 18 AWG 2 m / 6 ft 7 in 10 A, 125 V
17512 Stripped SJT, 18 AWG 2 m / 6 ft 7 in 10 A, 125 V
17513 Stripped SJT, 18 AWG 3 m / 9 ft 10 in 10 A, 125 V
17514 Stripped SJT, 16 AWG 2 m / 6 ft 7 in 13 A, 125 V
17534 Stripped SVT, 18 AWG 2 m / 6 ft 7 in 10 A, 125 V
17535 Stripped SVT, 18 AWG 3 m / 9 ft 10 in 10 A, 125 V

🌍 International and Jumper Power Cords

Select the destination-specific plug before choosing the equipment connection. The international models below are rated 10 A at 250 V. Most provide a C13 connector, while the UK 209-02 has stripped conductors and the 365-010 jumper links a C14 output to a C13 input.

China

GB-2099-1-1996 to C13
2.5 m • RVV 3 × 1.0 mm² • CCC

View 196-000 →

Continental Europe

CEE 7/7 to C13
2.5 m • H05VV-F 3G1.0 mm² • straight or right-angle plug

Straight 199-000 | Right-angle 199-020

United Kingdom

BS 1363 to stripped ends
2.5 m • H05VV-F 3G1.0 mm² • BSI/ASTA

View 209-02 →

Italy

CEI 23-16 to C13
2.5 m • H05VV-F 3G1.0 mm² • IMQ

View 364-010 →

Israel

SI-32/12/88 to C13
2.5 m • H05VV-F 3G1.0 mm² • SII

View 457-010 →

Universal Jumper

C14 to C13
1 m / 3 ft 3 in • SJT 18 AWG / H05VV-F 3G1.0 mm²

View 365-010 →

🏥 Hospital-Grade Power Cords

For medical or dental equipment, start with the equipment manufacturer’s required cord specification and the facility’s electrical rules. These North American hospital-grade models use NEMA 5-15P plugs and C13 connectors with UL and CSA approvals.

458-M10315

4.6 m / 15 ft • SJT 16 AWG
13 A, 125 V
Clear housing

458-M121

3.1 m / 10 ft • SJT 18 AWG
10 A, 125 V
Gray housing

458-M161

3.1 m / 10 ft • SJT 18 AWG
10 A, 125 V
Clear housing

⚙️ Where These Cords Fit

  • Industrial PCs, monitors and operator workstations
  • Test equipment and benchtop instruments
  • Control-system peripherals with C14 inlets
  • OEM equipment requiring stripped-wire termination
  • Qualified medical and dental equipment installations

✅ Selection Checklist

  • Confirm the wall plug and destination country.
  • Identify C13, right-angle C13, C14 or stripped ends.
  • Never exceed the cord’s current or voltage rating.
  • Allow enough length without creating a trip hazard.
  • Verify approvals required by the equipment and installation.

❓ Mega Electronics Power Cord FAQ

What is the difference between detachable and non-detachable power cords?

A detachable cord uses a connector such as an IEC 60320-C13 that plugs into equipment with a matching C14 inlet. A non-detachable model ends in stripped conductors for permanent termination inside approved equipment.

When should I choose a right-angle C13 connector?

A right-angle C13 can reduce the space needed behind equipment and redirect the cable away from an enclosure or wall. Confirm the exit direction and available clearance before ordering.

Can a North American cord be used internationally with an adapter?

A plug adapter does not change the cord’s voltage, current or certification. Use a destination-approved cord and confirm that the connected equipment supports the local supply voltage and frequency.

Does a hospital-grade plug make any device suitable for patient-care areas?

No. The complete device and installation must meet the applicable medical and facility requirements. Match the cord to the equipment manufacturer’s specifications and obtain approval from the responsible safety authority.

Need Help Matching a Plug, Connector or Rating?

Let us know the location, equipment inlet, voltage, current and required length for a power cord recommendation.

Email our Sales Team