Mencom MDC M12 Molded Cordset Part Number Guide



Generated part number

Part Number

Describe the cable you need

Example: “5 pole male right angle, 4 meter black PUR cable with a stainless steel coupling nut.” Apply the description, then review the selections below.

Code follows the MDC prefix.

Code: 2, 3, 4, 5, 6, 8 or 12.

The configuration code follows the pole count.

4. Wire gauge option

Blank uses the standard 22 AWG for the selected cable.

Standard: 1M, 2M, 4M, 5M, 6M, 10M and 15M.

Use R for configurations other than MFRP or MRFP.

The default color may depend on cable type.

Armor code is placed before the coupling nut code.

SS is the final suffix when selected.

Build status: Choose the cable type, pole count, configuration and length.

View every part number code (Click to expand)

MDC[cable type]-[poles][configuration][X]-[length]-[angle]-[color]-[armor]-[coupling nut]

Blank/default suffixes are omitted. Example: PVC + 5-pole male + 4 meters + straight + yellow + no armor + nickel-plated brass becomes MDC-5MP-4M.

PositionCodesMeaning
Cable typeBlank, B, P, PQ, PM, PB, M, W, WFPVC; PVC/braided; PUR; PUR/coiled; PUR/foil; PUR/braided; foil shield; TPE; TPE/Hi-Flex
Poles2, 3, 4, 5, 6, 8, 12Number of connector poles
ConfigurationMP, FP, MFP, MFRP, MRFP, FSP, MFPS, MFSP, MSFPConnector gender, angle pairing and shield-to-nut arrangement
Wire gaugeBlank, XAppend X to the configuration for 18 AWG
Length1M, 2M, 4M, 5M, 6M, 10M, 15MStandard cable lengths in meters
AngleBlank, RStraight or right angle; MFRP and MRFP already define mixed angles
ColorBlank, B, GYYellow, black or gray
ArmorBlank, A01, A02, A02T, A03, A04, A50, A51No armor, stainless steel, PVC-covered stainless steel or silicone options
Coupling nutBlank, SSNickel-plated brass or stainless steel
Option explanations and material selection help (Click to expand)

MDC connector family

MDC means Micro DC. These are M12 A-coded cables.

PVC cable

Polyvinyl chloride is the industry-standard cable material and is rated from -40°C to 105°C.

PUR cable

Polyurethane resists oil and abrasion and is rated from -40°C to 80°C.

TPE cable

Thermoplastic elastomer resists weld slag and is rated from -40°C to 90°C.

Foil shield

A layer of aluminum between the wires and insulation provides 100% coverage.

Braided shield

A braided network of thin wires provides greater durability.

Stainless steel armor

A01 is crush resistant and stands up to corrosion and abrasion. A02 uses discrete wires, while A02T adds discrete Teflon wires for high-temperature applications.

Covered armor and silicone

A03 and A04 use liquid-tight, abrasion-resistant PVC-covered stainless steel. A50 and A51 use silicone for chemical, weld-slag and high-temperature resistance.