The Red Lion PAXLTC00 PAX LTC Lite series thermocouple temperature panel meter has a 4 digit, red LED display in a 1/8 DIN housing. It takes inputs from thermocouples and linearizes them, while compensating for cold junction, NBS linearity, and zero & span. Another mode of operation includes use as a millivolt meter, which shows the voltage at the thermocouple probe junction. It also has diagnostic features that can alert the user in the event of a performance problem. AC powered. This panel meter is not designed to directly command motors, valves, or actuators without safeguards.
Features
- 1/8 DIN Housing
- 4 Digit, Red LED Display
- 3 Function Keys Program Device
- Programmable TC Type (T, E, J, K, R, S, B, N or mV Scale)
- Conforms to ITS-90 Standards
- Selectable °F or °C with 0.1 (T, E, J, K and N only) or 1 degree display resolution
- Programmable Temperature Offset
- Programmable Digital Filtering Enhances Stability
- Hi/Lo Reading Memory
- NEMA 4X/IP65 - Front Panel
Red Lion PAX LTC Lite Series User Manual
PAXLTC00 Temperature Panel Meter with 1/8 DIN Housing
Display 4 digit, 0.56" (14.2 mm) red LEDs Power Requirements AC POWER: 85 to 250 VAC, 50/60 Hz, 6 VA Isolation: 2300 Vrms for 1 min. between input and supply (300 V working voltage) Input Impedance: 20 MOhm, all types Lead Resistance Effect 20 µV/350 Ohm Max Input Voltage Protection: 70 VDC continuous Cold Junction Compensation: Automatic, 0.02 degree/degree. Disabled for linear mV scale. Reading Rate: 2.5 readings/second Response Time: 2 seconds to settle for step input (increases with programmable digital filtering) Low Frequency Noise Rejection Normal Mode Rejection: 45 dB @ 50/60 Hz (may be improved by programmable digital filtering) Common Mode Rejection: 120 dB, DC to 50/60 Hz Standards Compliance UL Recognized Component, File # E179259, UL61010-1, CSA C22.2 No. 61010-1 UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95 Type 4X Enclosure rating (Face only), UL50 IECEE CB Scheme Test Report # 04ME11209-20041018 IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1. IP65 Enclosure rating (Face only), IEC 529 Electromagnetic compatibility: See user manual Physical Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -40 C to 80 C (-40 F to 176 F) Humidity: 85% max. relative humidity (non-condensing) Vibration to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z direction for 1.5 hours, 2g's. Shock to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions Span Drift: 40 ppm/°C Zero Drift: 1 µV/°C Altitude: Up to 2000 meters Construction: NEMA 4X/IP65 outdoor use, One piece bezel/case; flame resistant; panel gasket & mounting clip Connection: High Compression Cage-Clamp Terminal Block Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 4.5 inch-lbs (0.51 N-m) max. Dimensions: 1.95" x 3.8" x 4.2"
|