Hirschmann SPIDER II 8TX

Your Price: $210.00
Item Number: 943957-001
Manufacturer: Hirschmann
Manufacturer Part No: SPIDER II 8TX

Quantity Discounts - Order a quantity in the range below to receive the discount

QuantityAmount
2 to 4$203.70
5 to 9$197.40
10 to 19$189.00
Entry Level Industrial ETHERNET Rail-Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s), 8 x 10/100BASE-TX, TP-cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 3-pin, no signaling contact  
Network size - length of cable
Twisted pair (TP) 0 - 100 m  
Multimode fiber (MM) 50/125 µm n/a  
Multimode fiber (MM) 62.5/125 µm n/a  
Single mode fiber (SM) 9/125 µm n/a  
Single mode fiber (LH) 9/125 µm (long haul transceiver) n/a  
Network size - cascadibility
Line - / star topology Any  
Power requirements
Operating voltage DC 9.6 V - 32 V  
Current consumption at 24 V DC max. 150 mA  
Power consumption max. 4.1 W; 14.0 Btu(IT)/h  
Service
Diagnostics LEDs (power, link status, data, data rate)  
Redundancy
Redundancy functions n/a  
Ambient conditions
Operating temperature 0 ºC to +60 ºC  
Storage/transport temperature -40 ºC to +70 ºC  
Relative humidity (non-condensing) 10% to 95%  
MTBF 98.8 years, MIL-HDBK 217F: Gb 25ºC  
Mechanical construction
Dimensions (W x H x D) 35 mm x 138mm x 121 mm  
Mounting DIN Rail 35 mm  
Weight 246 g  
Protection class IP 30  
Mechanical stability
IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks  
IEC 60068-2-6 vibration 3,5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;
1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
 
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge  
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)  
EN 61000-4-4 fast transients (burst) 2 kV power line, 4 kV data line  
EN 61000-4-5 surge voltage power line: 2 kV (linie/earth), 1 kV (linie/line), 1 kV data line  
EN 61000-4-6 conducted immunity 10 V (150 kHz - 80 kHz)  
EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A  
EN 55022 EN 55022 Class A  
Approvals
Safety of industrial control equipment cUL 508 (E175531) pending  
EMV regulations for assembly in vehicles n/a  
Hazardous locations n/a  
Employment in vehicles n/a  
Safety of information technology equipment n/a  
Germanischer Lloyd n/a  
Scope of delivery and accessories
Scope of delivery Device, terminal block, operating manual  
Accessories to order separately Rail power supply RPS 30, RPS 80 EEC or RPS 120 EEC,
19" installation frame