Privacy Policy
Return Policy
Frequently Asked Questions

|
Hirschmann RS2-TX
|
Item Number: 943686-003
Manufacturer: Hirschmann
Manufacturer Part No: RS2-TX
|
|
Unmanaged Industrial ETHERNET Rail Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) 8 x 10/100Base-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
|
| More Interfaces |
|
| Power supply/signaling contact |
1 plug-in terminal block, 5-pin |
|
Network size - length of cable |
|
| Twisted pair (TP) |
0 - 100 m |
|
Network size - cascadibility |
|
| Line - / star topology |
any |
|
Power requirements |
|
| Operating voltage |
24 V DC (-25% to +30%) |
| Current consumption at 24 V DC |
max. 290 mA |
| Power consumption |
max. 7,0 W at 24 V DC |
|
Service |
|
| Diagnostics |
LEDs (power, link status, data,
error), signal contact / fault relay (24 V DC / 1 A) |
|
Redundancy |
|
| Redundancy functions |
redundant 24 V power supply |
|
Ambient conditions |
|
| Operating temperature |
0ºC to +60ºC |
| Storage/transport temperature |
-25 ºC to +70 ºC |
| Relative humidity
(non-condensing) |
10% to 95% |
| MTBF |
61 years; MIL-HDBK 217F: Gb 25 ºC |
|
Mechanical construction |
|
| Dimensions (W x H x D) |
47 mm x 135 mm x 111 mm |
| Mounting |
DIN Rail 35 mm |
| Weight |
230 g |
| Protection class |
IP20 |
|
Mechanical stability |
|
| IEC 60068-2-27 shock |
15 g, 11 ms duration, 18 shocks |
| IEC 60068-2-6 vibration |
1 mm, 2 Hz - 13.2 Hz, 90 min.;
0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1
octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
|
EMC interference immunity |
|
| EN 61000-4-2 electrostatic
discharge (ESD) |
6 kV contact discharge, 8 kV air
discharge |
| EN 61000-4-3 electromagnetic
field |
10 V/m (80 - 1000 MHz) |
| EN 61000-4-4 fast transients
(burst) |
2 kV power line, 1 kV data line |
| EN 61000-4-5 surge voltage |
power line: 2 kV (line/earth), 1
kV (line/line), 1 kV data line |
| EN 61000-4-6 conducted
immunity |
3 V (10 kHz - 150 kHz), 10 V (150
kHz - 80 MHz) |
|
EMC emitted immunity |
|
| FCC CFR47 Part 15 |
FCC CFR47 Part 15 Class A |
| EN 55022 |
EN 55022 Class A |
|
Approvals |
|
| Safety of industrial control
equipment |
cUL 508 (E175531) |
| Hazardous locations |
cUL 1604 Class 1 Div 2 (E203960) |
| Safety of information
technology equipment |
cUL 60950 (E168643) |
| Germanischer Lloyd |
Germanischer Lloyd (15 662 - 00 HH) |
|
Scope of delivery and accessories |
|
| Scope of delivery |
device, terminal block, operating
manual |
| Accessories to order
separately |
rail power supply RPS 30, RPS 80
EEC or RPS 120 EEC, 19" installation frame |
|
|
|