Privacy Policy
Return Policy
Frequently Asked Questions

|
Hirschmann RS2-5TX/FX
|
Item Number: 943732-103
Manufacturer: Hirschmann
Manufacturer Part No: RS2-5TX
|
|
Unmanaged Industrial ETHERNET Rail-Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) 4 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity, 1 x 100BASE-FX, MM cable, MTRJ sock
|
| Power supply/signaling contact |
1 plug-in terminal block, 5-pin /
no signal contact |
|
Network size - length of cable |
|
| Twisted pair (TP) |
0 - 100 m |
| Multimode fiber (MM) 50/125 µm |
0 - 5000 m, 8 dB link budget at
1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km |
| Multimode fiber (MM) 62.5/125
µm |
0 - 4000 m, 11 dB link budget at
1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km |
|
Network size - cascadibility |
|
| Line - / star topology |
any |
|
Power requirements |
|
| Operating voltage |
24 V DC (-25% to +30%) |
| Current consumption at 24 V DC |
max. 180 mA |
| Power consumption |
max. 4,0 W at 24 V DC |
|
Service |
|
| Diagnostics |
LEDs (power, link status, data,
error) |
|
Redundancy |
|
| Redundancy functions |
redundant 24 V power supply |
|
Ambient conditions |
|
| Operating temperature |
0 ºC to +60 ºC |
| Storage/transport temperature |
-25 ºC to +70 ºC |
| Relative humidity
(non-condensing) |
10% to 95% |
| MTBF |
74,4 years; MIL-HDBK 217F: Gb 25
ºC |
|
Mechanical construction |
|
| Dimensions (W x H x D) |
40 mm x 145 mm x 80 mm |
| Mounting |
DIN Rail 35 mm |
| Weight |
520 g |
| Protection class |
IP 20 |
|
Mechanical stability |
|
| IEC 60068-2-27 shock |
15 g, 11 ms duration, 18 shocks |
| IEC 60068-2-6 vibration |
3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1
octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
|
EMC interference immunity |
|
| EN 61000-4-2 electrostatic
discharge (ESD) |
4 kV contact discharge, 8 kV air
discharge |
| EN 61000-4-3 electromagnetic
field |
10 V/m |
| EN 61000-4-4 fast transients
(burst) |
2 kV power line, 1 kV data line |
| EN 61000-4-5 surge voltage |
power line: 1 kV (line/earth), 0.5
kV (line/line), 1 kV data line |
| EN 61000-4-6 conducted
immunity |
10 V (150 kHz - 80 MHz) |
|
EMC emitted immunity |
|
| FCC CFR47 Part 15 |
FCC CFR47 Part 15 Class A |
| EN 55022 |
EN 55022 Class A |
|
Approvals |
|
| Safety of industrial control
equipment |
cUL 508 (E175531) |
| Safety of information
technology equipment |
cUL 60950 (E168643) |
|
Scope of delivery and accessories |
|
| Scope of delivery |
device, terminal block, operating
manual |
| Accessories to order
separately |
rail power supply RPS 30, RPS 80